FordMPV Forum

Large MPVs -- Ford Galaxy / VW Sharan / SEAT Alhambra: => Ford Galaxy / VW Sharan / SEAT Alhambra => Common faults and problems / Knowledge Base => Topic started by: Hej-Hej on September 01, 2016, 09:14:22 AM

Title: Ford Galaxy - Enabling global opening / closing via remote control
Post by: Hej-Hej on September 01, 2016, 09:14:22 AM
Just succeeded to enable this feature on my 2002 Galaxy, and decided to make a guide how i did it, hope someone finds it useful :)

This feature is already available in the cars software but disabled by default, the following shows how to activate it which will allow remote operation of all windows / sunroof.

[youtube]https://www.youtube.com/watch?v=Q4PIEbYH5OM&feature=youtu.be[/youtube]

First of all you need the following:


First thing to do then, is to edit “VG.cfg” file in VDS-PRO folder, to allow us to write to eeprom, simply open in notepad and replace it all with this:

Code: [Select]
Screen Color
COMPort 1
StartBaud Fixed
BaudFixed 10472
BaudTry_1 10472
BaudTry_2 9600
BaudTry_3 4800
BaudTry_4 2400
BaudTry_5 1200
BaudTry_6 600
t_r0_usec 5000000
t_r4_usec 40000
t_r6_usec 1000
t_r6_ack_usec 1000
t_r6max_usec 150000
t_rb_usec 60000
t_rb_ack_usec 30000
t_rb_idle_usec 600000
t_rbmax_usec 1100000
t_rkmax_usec 800000
StartAddress 00000009
ConnectRetries 3
TimeStamp 5351883
NewMWGroupPreAck JA
AbortDebugMsgs NEIN
HugeMWDisplay JA
HexMWDisplay NEIN
LogTimeStamp NoStamp
LogMode Symbolic
LogCount 2569235
LogFileMode Request
LogBuffer LogBufferKb
LogBufferKb 32
LogFirstID JA

Then restart the computer and boot in to DOS, start VDS-pro and follow these steps:
(to navigate to VDS folder when in DOS, type “cd vds-pro” and hit enter, then type “vag” and hit enter again to open up VDS-PRO)

[attachimg=1]

With new .cfg file controller 09 should open on startup, but if you see this screen open “09 – electronic switchboard” by typing “09” with keyboard.

[attachimg=2]

Then controller 09 will open, be sure that baudrate is set to 10472

[attachimg=3]

Now type “11” to log in

[attachimg=4]

Password is ”21318” alt+O to select ”OK”

[attachimg=5]

Then type ”20” for RAM read, and enter adress 61003, alt+O to select “OK”

[attachimg=6]

By default the first digit should be 17 (right below the 0) alt+O to close

[attachimg=7]

Type “27” to open EEPROM (serial) write, and type “61003” in address and “19” in value. Then alt+O

[attachimg=8]

Now if you open “20 – RAM read” again, you should see the new value of “19” alt+O
Alt+X to close down VDS-PRO, cycle ignition and enjoy your remoted windows!

Quote from: FordMPV.com
Question? Something not quite make sense?
Posts in the reference library are locked but you can start a new topic on the subject by clicking here
(https://www.fordmpv.com/smf2/technical/?action=post)